DARKO Glycol Chillers deliver reliable temperature control from 0°C to -15°C (-5°C/-10°C/-10°C models available), engineered for critical cooling applications across multiple industries. Our industrial-grade chillers ensure process stability and energy efficiency for temperature-sensitive operations.
Description
Technical Parameters
Detail Images
Precision Glycol Chillers For Brewing,Beverage,Dairy Pharmaceutical Manufacturing

Glycol Chiller Features:

✔ Precise Temperature Range: 0°C, -5°C, -10°C and -15°C chilled glycol output
✔ Multi-Industry Compatibility:

Biofermentation & Pharmaceutical Manufacturing

Beverage Production (Beer, Juice, Soft Drinks)

Dairy & Milk Processing

Winemaking & Brewery Operations

Food Processing & Preservation
✔ Energy-efficient design reduces operational costs
✔ Corrosion-resistant components for extended lifespan
✔ Intelligent temperature control (±0.5°C accuracy)

Why Choose Our Glycol Chiller Systems?

Our chillers are specifically designed for process cooling applications requiring sub-zero temperatures. The non-freezing glycol solution prevents ice formation while maintaining consistent cooling performance, making it ideal for:

• Fermentation tank temperature control
• Product line rapid cooling
• Batch process thermal management

• Equipment heat recovery systems


Technical Specifications:

  • Cooling Capacity: 5kW to 1000 kW

  • Flow Rate: 15 L/min to 4000 L/min

  • Refrigerant: Eco-friendly R407C,R404a,R507,R134A,R410A

  • Custom configurations available

  • Certifications: ISO 9001, CE

  • Evaporator : High Efficiency Shell and tube, or tank with coil

  • Compressor: Energy-Efficient Hermetic Scroll,No need maintenance

  • Completely protection system for the whole air cooled chiller

Industry-Proven Performance

Trusted by food processing plants, breweries, and pharmaceutical facilities worldwide, our glycol chilling systems meet strict hygiene standards with:
• Stainless steel pump, pipe system
• Intelligent remote control
• Stainless steel heat exchangers

Optimize your production line with precise temperature control - [Contact Us] today for a free cooling system consultation!

10HP WATER CHILLER (11).jpg

Portable Air Cooled Glycol Chiller 

40HP WATER CHILLER  (15).jpg

40HP Industrial Glycol Chiller

 Model

DK-3AL

TDK-5AL

DK-6AL

DK-8AL(D)

DK-10AL(D)

DK-12AL(D)

Cooling capacity

At 0℃ Outlet (Kw)

6.8

10.5

12.2

16.2

22.8

24.8

At -5℃ Outlet (Kw)

5.7

8.9

10.3

13.8

19.3

21.0

Power

Kw

3.45

5.45

6.31

8.22

10.54

12.33

Power Supply

3PH-380V-50Hz

Refrigerant

Type

R22/R407C/R404a

Control

Thermostatic expansion valve

Compressor

Type

Hermetic scroll type

Power(Kw)

2.84

4.36

5.2

3.5*2

4.4*2

5.2*2

Evapoirator

Type

SS Tank with coil or Shell and tube Or Plate Heat Exchanger

At 0℃ OutletWater Flow(m3/h)

1.29

1.99

2.31

3.07

4.32

4.70

At -5℃ OutletWater Flow(m3/h)

1.17

1.83

2.12

2.84

3.97

4.32

Capacity(L)

50

70

70

120

200

200

Inlet/Outlet

DN20

DN20

DN32

DN32

DN32

DN32

Condenser

Type

High efficiency hydrophilic aluminum foll finned type

Fan Power(Kw)

0.25

0.52

0.52

0.24*2

0.52*2

0.52*2

Pump

Type

Centrigual water pump

Power(Kw)

0.37

0.55

0.55

0.55

0.55

0.55

Lift(m)

24

25

24

20

20

20

Protection System

Compressor overheat protection, high/low pressure protection, phase missing/sequence protection, flow rate protection, anti-frozen protection.

Dimension

L (mm)

700

900

900

950

1560

1560

W (mm)

550

850

850

900

850

850

H (mm)

1000

1800

1800

1900

1500

1500

Weight

Kg

150

200

230

310

450

500

Model

DK-15AL(D)

TC-20C(D)

DL-25AL(D)

DK-30AL(T)

DK-40AL(F)

DK-50AL(F)

Cooling capacity

At 0℃ Outlet (Kw)

33.4

44.2

50.5

66.9

87.7

110.6

At -5℃ Outlet (Kw)

28.4 a

37.6

43

56.8

74.5

94

Power

Kw

15.84

20.51

23.52

31.81

40.18

47.92

Power Supply

3PH-380V-50Hz

Refrigerant

Type

R22/R407C/404a

Control

Thermostatic expansion valve

Compressor

Type

Hermetic scroll type

Power(Kw)

6*2

8.7*2

10.2*2

8.7*3

8.7*4

10.2*4

Evapoirator

Type

SS Tank with coil or Shell and tube Or Plate Heat Exchanger

At 0℃ OutletWater Flow(m3/h)

6.33

8.37

9.57

12.68

16.62

20.96

At -5℃ OutletWater Flow(m3/h)

5.84

7.73

8.85

11.68

15.33

19.34

Capacity(L)

270

350

350

450

580

580

Inlet/Outlet

DN40

DN40

DN40

DN65

DN65

DN80

Condenser

Type

High efficiency hydrophilic aluminum foll finned type


Fan Power(Kw)

0.55*2

0.75*2

0.75*2

0.75*2

1.5*2

0.75*4

Pump

Type

Centrigual water pump


Power(Kw)

1.5

1.5

1.5

2.2

2.2

2.2

Lift(m)

20

20

20

21

20

19

Protection System

Compressor overheat protection, high/low pressure protection, phase missing/sequence protection, flow rate protection, anti-frozen protection.

Dimension

L (mm)

1800

2100

2100

2200

2500

2000

W (mm)

1000

1000

1000

1160

1460

2000

H (mm)

1600

1700

1700

1900

2000

1750

Weight

Kg

750

850

900

1150

1350

1600

Note

1.Nominal cooling capacity conditions:chilled water in 5/0℃,out 0/-5℃;cooling water in 30℃,out35℃

2. .Specifications are subject to change without notice for futher improvement.

Water Chiller Control System


DARKO has developed a highly intelligent PLC and PC-level computer control system, which can be used for remote monitoring and control. Simple operation, connect with power supply directly, with lower failure, and high safety factor, easy installation. User can set the parameter as real working need, intuitive and reliable; SIEMENS PLC is workable.

10HP CHILLERS (3).jpg

LCD or Touch Type Panel


30hp chiller (27).jpg

Schneider Brand Electric Components


Industrial Water Chiller Compressor

It adopt the world famous brand hermetic scroll type compressor, which can saving 20-30% energy than the reciprocating compressor. It's running more stably, reliably, with high efficiency, fewer failures, less vibration, lower noise and easy maintenance. The compressors can automatically running alternately according to the load change, to balance the running speed of each compressor, and greatly extend the service life of the chiller.

Water Chiller32.png

Emerson Copeland Scroll Compressor 


Air Cooled Chiller (10).jpg

Japan Panasonic Scroll Compressor 


Heat Exchanger -Evaporator

(1). Tank with coil: If customer will connect with a closed water loop;

(2). Shell and tube: If customer will connect with a open water loop;

(3). Plate Heat Exchanger: It can connect with glycol tank, or extra tank directly, same operate with shell and tube;

(4). It adopts internal and external threaded tubes, the inner surface of the copper tube is threaded and surface is smooth, the cooling efficiency is higher. The outside of the evaporator is insulated with 25mm thick PE insulation board, no condensation, and small loss of cooling capacity.

Evaporators.png

Tank With Coil


Shell and tube.png

Shell And Tube


857201012483809_副本.jpg

Plate Heat Exchanger


Condenser

Equipped with high-efficiency transverse slit fins and internal threaded copper tubes, with high heat exchange efficiency and good stability.

WATER CHILLER (9).jpg

High efficiency hydrophilic aluminum foll finned type

Internal Water Pump

SCROLL CHILLER (2).jpg

PowerFul Fan


CNP Chiller Pump.png

DARKO Industrial Glycol Water Chiller with best price,  widely application:

Brewery, winery, fermentation workable for -5C chiller; Or lower outlet such as -10C, -15C; you can send me message to get the detailed specification.

10HP WATER CHILLER (13).jpg

Smaller & Portable Glycol Chillers

20HP WATER CHILLER  (10).jpg

10TR Glycol Chiller Unit 

30hp water chiller.png

30HP Air Cooled Glycol Chillers

Glycol Chillers (4).jpg

40HP Industrial Glycol Chiller 

Industrial Chiller (3).png

50HP Brewery Glycol Chillers 

100HP AIR CHILLER.png

Customized Larger Capacity Glycol Chiller With Scroll Compressor


Online Consultation

Cooling Equipment Fill:
Submit

Related Recommendations